NV11 Manual Set – Section 5
Action
Note Dispensed at Power Up
Note Float Removed
Note Float Attached
Note in Bezel Hold
Device Full
SMART Emptying
SMART Emptied
Channel Disable
* When enabled using option flag.
Notes:
Action
Command Not Known: Returned when an invalid command is received by a
Wrong Number Of
Parameters:
Parameter Out Of
Range:
Command Cannot Be
Processed:
Software Error:
Key Not Set:
Jammed:
Copyright © Innovative Technology Ltd 2012
Command Code (Hex)
0xCD, value/channel of note
0xC7
0xC8
0xCE, value/channel of note
0xCF
0xB3
0xB4
0xB5
Comments
peripheral.
A command was received by a peripheral, but an incorrect
number of parameters were received.
One of the parameters sent with a command is out of
range.
A command sent could not be processed at that time.
Reported for errors in the execution of software e.g.
Divide by zero. This may also be reported if there is a
problem resulting from a failed remote firmware upgrade,
in this case the firmware upgrade should be redone
The slave is in encrypted communication mode but the
encryption keys have not been negotiated
Five-byte response that indicates that the validator is
jammed; this is reported until it is un-jammed or reset. It
will also become disabled.