NV11 Manual Set – Section 4
Caution!
Be careful cleaning sensors.
Cleaning the belts is a simple operation. Ensure the validator is enabled (i.e. bezel
lights are illuminated), then remove the bezel:
The bezel is
removed by pushing
the red locking arms
on both sides of the
validator upwards,
and sliding the bezel
away from the
locking arms
Lift the bezel off
once the bezel has
been slid fully
across and is clear
of the locating pins
Copyright © Innovative Technology Ltd 2012
When cleaning the recessed front sensor, use a
small soft brush or cotton bud – do not use
anything sharp or abrasive.
b. Slide bezel away from
locking arms
Lift upwards to remove
a. Push locking arms upwards
32
Locating pins
GA963-2