Innovative Technology NV11 User Manual page 142

Table of Contents

Advertisement

NV11 Manual Set – Section 5
Action
Payout Note:
Stack Note:
Set Value Reporting
Type:
SMART empty:
Cashbox Payout
Operation Data:
Copyright © Innovative Technology Ltd 2012
Comments
This is a single byte command. The Note Float module
will pay out the last note that was stored. This is the
note that is in the highest position in the table returned
by the Get Note Positions Command. If the payout is
possible the Note Float will reply with the generic
response 'OK'.
This is a single byte command. The Note Float module
will stack the last note that was stored. This is the note
that is in the highest position in the table returned by the
Get Note Positions Command. If the stack operation is
possible the Note Float will reply with the generic
response 'OK'.
Two-byte command. This will set the method of
reporting values of notes. There are two options, by a
four-byte value of the note or by the channel number of
the value from the banknote validator. If the channel
number is used then the actual value must be
determined using the data from the Validator command
Unit Data. The default operation is by 4-byte value.
Empties the Note Float module of notes, maintaining a
count of value emptied. The note counters will be set to
0 after running this command. Use 'cashbox payout
operation data' command to retrieve a breakdown of the
denominations routed to the cashbox through this
operation.
This command can be sent at the end of a SMART
Empty, float or dispense operation. Returns the amount
emptied to cashbox from the Note Float in the last
dispense, float or empty command. The quantity of
denominations in the response is sent as a 2 byte little
endian array; the note values as 4-byte little endian
array and the country code as a 3-byte ASCII array. Each
denomination in the dataset will be reported, even if 0
notes of that denomination are emptied.
9