Configuration Manual
Ascom i62 VoWiFi Handset
The following alarm types can be configured; Push-button alarm, Test alarm, Emergency call
alarm, Man-down and No-movement alarm.
6.8.1
Common Alarm Settings
These settings are common for all alarms sent from the handset.
1
Select Alarm > Common.
2
In the Stored alarm data field, enter data to be sent along with an alarm (optional).
3
In the Indicate initiated Alarm drop-down list, select one of the following:
• On - The handset will beep and the LED will flash twice when an alarm is initiated.
• Off - The handset will not indicate when an alarm is initiated.
4
In the Disable backlight during alarm drop-down list, select one of the following:
• Yes - The display backlight will be left unchanged for 30 seconds after alarm
• No - The display will light up after an alarm.
6.8.2
Push Button Alarm
1
Select "Alarm".
2
Select "Multiple-press" or "Long-press".
3
In the Alarm type for multiple press drop-down list or Alarm type for long press drop-
down list, select "Push button alarm 1".
4
In the Number for automatic call after alarm field, enter the number to be called after
an alarm has been activated (optional).
5
In the ALS drop-down list, select "Yes" if an Acoustic Location Signal shall sound
when the alarm has been activated.
6
In the Text indication for alarm on multiple press field or Text indication for alarm on
long press, enter the text to be displayed in the handset when the alarm has been
activated.
7
In the Mode for automatic call after alarm drop-down list, select one of the following:
• Monitor - The loudspeaker is muted and the microphone is on.
• Loudspeaker - The loudspeaker is turned on.
• Ordinary - The loudspeaker is turned off.
6.8.3
Test Alarm
1
Select "Alarm".
2
Select "Multiple-press" or "Long-press".
3
In the Alarm type for multiple press drop-down list or Alarm type for long press drop-
down list, select "Test alarm".
4
In the Number for automatic call after alarm field, enter the number to be called after
an alarm has been activated (optional).
5
In the ALS drop-down list, select "Yes" if an Acoustic Location Signal shall sound
when the alarm has been activated.
6
In the Text indication for alarm on multiple press field or Text indication for alarm on
long press, enter the text to be displayed in the handset when the alarm has been
activated.
20 June 2012 / Ver. E
6. Handset Configuration
TD 92675EN
48
Need help?
Do you have a question about the i62 and is the answer not in the manual?
Questions and answers
no access solving
To solve access issues with the Ascom i62, follow these steps:
1. Login to the Device:
- Enter the phone's IP address in the browser.
- Click the login link in the top right corner.
- Enter the username “admin” and password “changeme”.
- Click OK.
2. Check Logs and Errors:
- Navigate to the Troubleshoot tab.
- Review the Syslog for real-time handset actions.
- Check the Errorlog for stored errors and download it if needed.
3. Review WLAN and Voice Statistics:
- Open the Statistics tab to check call and WLAN connectivity details.
4. Wi-Fi Configuration Adjustments:
- Ensure consistent transmission power across all APs.
- Avoid large power variations set by ARM.
- Match AP channels with the i62 configuration.
- If connectivity is intermittent, test with one AP first, then expand.
5. SSID Profile Optimization:
- Use a clean SSID profile and apply optimizations step by step.
- Observe behavior after each change to identify potential issues.
If the issue persists, provide logs to Ascom support for further analysis.
This answer is automatically generated