8.6

Alarm/Door Bell

The system can monitor external contacts as Alarm or Door Bell inputs.
The number of contacts varies based on the iPECS platform and size.
Alarm — should the external contact activate, a unique Alarm Ring signal
and LCD display may be received. To restart the monitor circuit, the
external contacts must be deactivated and the Alarm Ring signal terminated.
Door Bell — a unique Door Bell ring (a single tone burst) may be received
each time the external contact is activated. A system contact also can be
assigned to act as a Door Open contact. You can then activate the contact
through dial codes or a flexible button assigned with the Door Open code.
To terminate the Alarm signal:
 Dial 565, the Alarm Stop code.
To activate the Door Open contacts:
 Lift the handset,
 Dial the Door Open code, #* and contact number.
8.7

System Voice Memo

The integrated Voice announcement module incorporates several Voice
Memos to provide you with general information such as station number,
date, time, and feature status. Voice Memos are heard over the iPECS
Phone speaker.
For the Station Status Memo, the following items are reported:
ICM Signaling Mode (Handsfree/Tone/Privacy)
Station IP Address
Station Mac Address
Number of messages x (x: number of all message waiting)
Wake-Up Time (hh:mm)
Do Not Disturb
Forwarded to station xxx
Forwarded to speed bin xxx
Queued CO/IP line xxx
Locked (Temporary COS)
COS x