Self-Diagnosis Code Table - Sony DCR-PC6E Service Manual

Hide thumbs Also See for DCR-PC6E:
Table of Contents

Advertisement

4.

SELF-DIAGNOSIS CODE TABLE

Self-diagnosis Code
Block
Detailed
Function
Code
C
0
4
0
0
C
2
1
0
0
C
2
2
0
0
C
3
1
1
0
C
3
1
1
1
C
3
1
2
0
C
3
1
2
1
C
3
1
2
2
C
3
1
2
3
C
3
1
2
4
C
3
1
3
0
C
3
1
4
0
C
3
1
4
2
C
3
1
1
0
C
3
1
1
1
C
3
2
2
0
C
3
2
2
1
C
3
2
2
2
C
3
2
2
3
C
3
2
2
4
C
3
2
3
0
C
3
2
4
0
C
3
2
4
2
E
6
1
0
0
E
6
1
1
0
E
6
2
0
0
E
6
2
0
1
Symptom/State
Non-standard battery is used.
Condensation.
Video head is dirty.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
Winding S reel fault when counting the
rest of tape.
T reel fault.
S reel fault.
T reel fault.
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum operations.
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
Winding S reel fault when counting the
rest of tape.
T reel fault.
S reel fault.
T reel fault.
FG fault when starting capstan.
FG fault when starting drum
FG fault during normal drum
operations
Difficult to adjust focus
(Cannot initialize focus.)
Zoom operations fault
(Cannot initialize zoom lens.)
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Use the info LITHIUM battery.
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Inspect the lens block focus reset sensor (Pin 7 of CF-085 board
CN3351) when focusing is performed when the focus ring is rotated
in the focus manual mode, and the focus motor drive circuit (IC204
of VC-265 board) when the focusing is not performed.
Inspect the lens block zoom reset sensor (Pin qh of CF-085 board
CN3351) when zooming is performed when the zoom lens is
operated and the zoom motor drive circuit (IC204 of VC-265 board)
when zooming is not performed.
Inspect pitch angular velocity sensor (SE3450 of CF-085 board)
peripheral circuits.
Inspect yaw angular velocity sensor (SE3451 of CF-085 board)
peripheral circuits.
— 9 —
Correction

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-pc9eDcr-pc9

Table of Contents