1-1.
Self-diagnosis Function
1-1-1.
Self-diagnosis Function
If an error occurs in this unit, the self-diagnosis function starts working and a code consisting of one alphabet and a five-
digit number appears on the LCD. Classification of persons in charge, classification of faulty blocks, and details of errors
can be checked by referring to this indication of six alphanumeric characters in the self-diagnosis code table.
The history of past errors can be checked in "Usage and Diag record" on the DATA tab of the Adjust Manual.
The self-diagnosis function is also described in the operation manual.
1-1-2.
Self-diagnosis Code Table
Self-diagnosis
Symptom/State
Code
A0-000
System error by software
E10-005
Lens overheating
E10-006
Lens overheating
E10-007
Handshake correction function does
not work well
E10-008
Handshake correction function does
not work well
E10-009
Image vibration correction during
handshake function does not work
E10-101
Abnormalities in initialization of the
zoom lens
E10-102
Abnormalities in initialization of the
focus lens and abnormalities in initi-
alization of the zoom lens occurred
simultaneously
E10-103
Abnormalities in initialization of the
lens
E10-104
Abnormalities in initialization of the
lens
E10-10A
Focus lens initializing failure
E12-001
Abnormality of the variable ND fil-
ter
E12-002
Abnormality of the variable ND fil-
ter
PXW-X160/PXW-X180
Section 1
Trouble Shooting
Correction
Ask the headquarters about correction of this error.
IC1301 on the VC-1030 board, IC6401 on the LD-1016 board, or the
peripheral circuit may be faulty.
Replace the faulty VC-1030 board, LD-1016 board, and/or the lens
block.
IC1301 on the VC-1030 board, IC6401 on the LD-1016 board, or the
peripheral circuit may be faulty.
Replace the faulty VC-1030 board, LD-1016 board, and/or the lens
block.
SE8501 on the GY-1006 board or the peripheral circuit may be faulty.
Replace the GY-1006 board.
SE8501 on the GY-1006 board or the peripheral circuit may be faulty.
Replace the GY-1006 board.
SE8501 on the GY-1006 board or the peripheral circuit may be faulty.
Replace the GY-1006 board.
IC1301 on the VC-1030 board, IC6001/IC6201/IC6301 on the
LD-1016 board, or the peripheral circuit may be faulty.
Replace the faulty VC-1030 board, LD-1016 board, and/or the lens
block.
IC1301 on the VC-1030 board, IC6001/IC6201/IC6301 on the
LD-1016 board, or the peripheral circuit may be faulty.
Replace the faulty VC-1030 board, LD-1016 board, and/or the lens
block.
IC1301 on the VC-1030 board or the peripheral circuit may be faulty.
Replace the faulty VC-1030 board and/or the lens block.
IC1301 on the VC-1030 board, IC6401 on the LD-1016 board, or the
peripheral circuit may be faulty.
Replace the faulty VC-1030 board, LD-1016 board, and/or the lens
block.
IC1301 on the VC-1030 board, IC6001/IC6201/IC6301 on the
LD-1016 board, or the peripheral circuit may be faulty.
Replace the faulty VC-1030 board, LD-1016 board, and/or the lens
block.
Replace the lens block.
Replace the lens block.
Continued
1-1