8. White Balance Adjustment (PD-148 board)

Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
D
Adjustment Address
A8, A9
Specified Value
The LCD screen should not be colored.
Note1: Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC2101
Note2: Use the AC power adaptor.
Adjusting method:
Order Page Address Data
1
0
01
01
2
D
A8
3
D
A9
4
D
A9
5
D
A8
6
D
A8
7
D
A9
8
D
A9
9
D
A9
10
0
01
00
Procedure
Set the data.
Set the following data, and press
PAUSE button.
7D: DCR-PC9/PC9E
79: DCR-PC6E
Set the following data, and press
PAUSE button.
65: DCR-PC9/PC9E
6F: DCR-PC6E
Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
Change the data so that the LCD
screen is not colored.
Press PAUSE button.
Change the data so that the LCD
screen is not colored.
Press PAUSE button.
If the LCD screen is colored,
repeat steps 5 to 9.
Set the data.
5-34