1-1-2.

Preparations

Note 1: For details of how remove the cabinet and boards, refer to "2.
DISASSEMBLY".
Note 2: When performing only the adjustments, the lens block and boards
need not be disassembled.
1)
Connect the equipment for adjustments according to Fig. 5-1-2.
Note 3: As removing the control switch block (FK-1770)(removing the
VC-265 board CN013) means removing the lithium 3V power
supply (BT601), data such as date, time, user-set menus will be
lost. After completing adjustments, reset these data. If the cabinet
(R) has been removed, the self-diagnosis data, data on history of
use (total drum rotation time etc. ) will be lost. Before removing,
note down the self-diagnosis data (data of page:2, address: B0 to
C6) and the data on history use (data of page: 2, address: A2 to
AA). (Refer to "SELF-DIAGNOSIS FUNCTION" for the self-
diagnosis data, and to "5-4.Service Mode" for the data on the
history use.)
Note 4: Setting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the control switch block (PS-1770) removed. After
completing adjustments, be sure to exit the "Forced Camera Power
ON Mode".
Note 5: Exiting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.