Checking the fuse
1. Check the fuse and fuse holder for conti-
nuity. Replace if there is no continuity.
Checking the wiring harness
(10 pins)
1. Check the wiring harness for continuity.
Replace if there is no continuity.
Checking the neutral switch
1. Check the neutral switch for continuity.
Replace if there is no continuity.
Brown (Br)
Free
Push
Checking the starter relay
1. Connect the digital circuit tester leads to
the starter relay terminals.
2. Connect the brown (Br) lead to the posi-
tive battery terminal.
3. Connect the black (B) lead to the nega-
tive battery terminal.
62Y5A11
Lead color
Brown (Br)
4. Check for continuity between the starter
relay terminals. Replace if there is no
continuity.
5. Check that there is no continuity between
the starter relay terminals after discon-
necting the brown or black lead. Replace
if there is continuity.