Function 1: System parameters

Function 15: System timing parameters

Function 151: Flash hook duration
This sets the time (in tenths of a second) that a flash hook will be sent on the current line to the
Telco. If this value is too short, the CO will not recognize the flash hook. The default setting of 15
(1.5 seconds) will cause disconnect and fresh dial tone from the CO.
Range: 2–20 (0.2–2.0 seconds).
Default: 15 (1.5 seconds).
Function 152: Transfer recall timer
This sets the number of times a transferred call will ring before following the extension's day/night
routing (typically to the extension's mailbox).
Range: 1–9 rings.
Default: 3 rings.
Function 153: Hold/park recall timer
This is the amount of time, in seconds, that a call will remain on hold or park before recalling to the
extension that initiated the park or hold.
Range: 5–960 seconds.
Default: 60 seconds.

Function 16: Recording alert

When using the live recording feature to record an outside call, the system can be set to play a
short beep tone every 15 seconds to indicate to both parties that recording is in progress.
Default: Disabled.
Warning:
IN MOST JURISDICTIONS, A CONVERSATION IS PERMITTED TO BE RECORDED IF ONE OF THE
TWO PARTIES IS AWARE THAT IT IS BEING RECORDED.
HOWEVER, ESI TAKES NO RESPONSIBILITY AS TO ITS LEGALITY IN ALL
JURISDICTIONS. IT IS THE RESPONSIBILITY OF THE INSTALLING COMPANY AND THE END
USER TO DETERMINE AND FOLLOW THE APPLICABLE STATE AND LOCAL LAWS REGARDING
RECORDING OF CONVERSATIONS.
D.2