Assembling The Unit - HearthStone Windsor Bay 8830 Owner's Manual And Installation Manual

Gas-fired direct vent heater
Table of Contents

Advertisement

HearthStone Quality Home Heating Products Inc

Assembling The Unit

You Will Need the Following to Complete the Installation:
Ø Surround Set (See Dimensions)
Ø Two – 3" Flex Liners (Dura-Vent #2280)
Ø Co-Linear Chimney Liner Termination Kit (Dura-Vent #923GK)
Ø High Wind Termination Cap (Dura-Vent #991)
Ø Four – 3.5" Hose Clamps
Ø Gas Hookup Equipment/Tools
Ø High Temperature Silicone
Ø Small Level
Ø Phillips Screwdriver
Ø Slotted Screwdriver or 5/16" Nut Driver
Ø Thread Sealant
Ø Open End Wrenches or Adjustable Wrench
Ø Permanent Marker
Ø Allen Wrench (supplied)
Before You Begin
Make sure the masonry fireplace and flue
comply with the applicable codes and are in
good condition. Repair any damage before
installation of the Windsor Bay begins.
Prepare a zero clearance (metal) fireplace by
doing the following:
• Remove the damper, grate, and log set.
• If necessary, remove the smoke shelf,
internal baffles, screen, masonry lining and
doors.
(see
Fireplace
requirements for on page 7)
• DO NOT remove any insulation or
structural frame members.
• DO NOT remove or alter the metal
sides, floor, doorframe, or face of the
fireplace.
Install a 3/8" gas line, or an appropriate size
to provide a sufficient gas supply to meet the
maximum demand of the unit without undue
loss of pressure, a gas shut-off valve, and a
sediment trap before installing the insert.
The gas line will enter the valve on the right
side of the unit.
I
NSTALLATION OF
L
INEAR
To complete the installation of the co-linear
venting system, you will need the following
components"
Ø Two Sections 3" Co-Linear Flex
Ø Chimney
Dimension
Ø High Wind Termination Cap. Dura-
Ø High Temperature Silicone.
Ø Four 3-1/2" Hose Clamps.
→ Mark each end of the flexible vent pipes
"intake" with a permanent marker. Mark
each end of the other flexible vent pipe
"exhaust".
→ Apply the high temperature silicone to
the top outer edge of both the intake and
exhaust collars on the back of the unit.
The exhaust adaptor is the collar in the
center of the unit. The intake adaptor
22
Windsor Bay Model #8830
T
HE
P
IPE
Extensions (10 ft min./30 ft max.).
Dura-Vent #2280
Liner
Termination
(includes
Co-Linear
Termination
and
Flashing).
Vent #923GK
Vent #930
C
-
O
Kit
to
Co-Axial
Dura-

Hide quick links: