HearthStone Windsor Bay 8830 Owner's Manual And Installation Manual page 37

Gas-fired direct vent heater
Table of Contents

Advertisement

HearthStone Quality Home Heating Products Inc
TROUBLESHOOTING (
Symptom
Possible Cause
10. Delayed
A. Incorrect air-to-fuel ratio.
ignition (makes a
A1. Primary air incorrect.
sudden "whoosh"
A2. Burner ports plugged.
noise as the burner
lights). This is a
buildup of gas's
prior to ignition.
This is more
prevalent with
propane (LP) fuel.
B. Improper log placement.
.)
CONT
Corrective Action
A1. Adjust the air shutter for a proper burn.
A2. Open ports to allow for proper travel of
flames.
B. Reposition logs to eliminate interference
with flame travel.
37
WINDSOR BAY Insert Model #8830

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents