Specifications - HearthStone Windsor Bay 8830 Owner's Manual And Installation Manual

Gas-fired direct vent heater
Table of Contents

Advertisement

HearthStone Quality Home Heating Products Inc

SPECIFICATIONS:

L
: D
V
ISTED
IRECT
ENT
G
H
AS
EATER
Listed: DV Gas Heater
Model: Windsor Bay
Direct Vent Insert Room
Heater
Testing Agency: Intertek
Testing Services NA Inc.
(ITS)
Tested to: ANSI Z21.88-
1998, CSA 2.33-M98,
Input rating (Btu/hr) 0-2000ft
Maximum output (Btu/hr) 0-2000ft
Minimum input rating (Btu/hr)
Orifice size DMS 0-2000ft
Man. pressure- HI setting (in.w.c./kPa)
Man. pressure- LO setting (in.w.c./kPa)
Inlet pressure-HI (in.w.c./kPa.)
Inlet pressure-Lo (in.w.c./kPa)
TOP
VIEW
FRONT
VIEW
LARGE SURROUND
Figure 1: Windsor Bay Dimensions
NG
32,000
24,000
20,000
46
3.5/0.87 10.0/2.48
1.6/0.42 6.4/1.59
10.5/2.6 14.0/3.47
5.0/1.24 11.0/2.88
Fireplace Dimensions: Minimum Maximum
*Allow 4" extra
for venting
connection
8
Windsor Bay Model #8830
SMALL SURROUND
LP
32,000
24,500
26,000
56
Fireplace Dimensions
Width:
28"
Height:
20"
Depth:
10"
42"
31"
>15"