HearthStone Windsor Bay 8830 Owner's Manual And Installation Manual page 30

Gas-fired direct vent heater
Table of Contents

Advertisement

HearthStone Quality Home Heating Products Inc
Controlling the Windsor Bay by the wall-
mounted thermostat may become erratic,
nonexistent, or the unit may go out, if the
pilot flame is too small or misdirected away
from the thermopile.
Figure 11: Pilot Adjustment
¦
W
ARNING
The control has an interlock device. If the
stove has been lit, it will not relight
immediately. After shutting off all gas flow,
the pilot burner cannot be relit until the
thermocouple
has
cooled,
electromagnet to be released (Approx. 60
sec.). The gas control knob is designed to
be operated by hand. Do not use any tools
during this operation.
B
F
A
URNER
LAME
Once the unit is lit, observe the flame
pattern and adjust as necessary. Also, a
periodic visual check of the burner flame
should be performed. The burner f l ames can
be adjusted by means of the air shutter. To
determine
if
the
adjustment, it is necessary to view the flame
pattern with the variable output control knob
at its highest setting (turn fully counter-
clockwise). Allow the unit to o perate for 10
minutes enabling the entire unit to reach
allowing
the
PPEARANCE
burner
flame
needs
WINDSOR BAY Insert Model #8830
temperature and for the flame pattern to
stabilize. The flame pattern should be
similar to the one shown in Figure 12. There
are several guidelines to aid in determining
if the flame pattern is correct:
1. The flame should not be dirty, smoky,
sooty, or lick the top of the stove.
2. The flame should not rise off of the
burner tube, called "lifting".
3. Flames should not impinge heavily on
the log set. They should "fit" through the
pre-formed spaces designed in the log
set.
Figure 12: Burner Flame Appearance
30