HearthStone 8762 User Manual

HearthStone 8762 User Manual

Gas-fired direct-vent heater installation & operating instructions

Advertisement

Quick Links

WARNING: FOLLOW THE INFORMATION IN
THESE INSTRUCTIONS EXACTLY, IF NOT, A FIRE
OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR
LOSS OF LIFE.
WARNING: DO NOT STORE OR USE GASOLINE
OR ANY OTHER FLAMMABLE VAPORS AND
LIQUIDS NEAR THIS OR ANY OTHER GAS
APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch electrical switches; do not use the phone
in your building.
Immediately call your gas supplier from a phone
outside the structure. Follow your gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire
department or 911.
A qualified installer, service agency, or gas supplier must
perform installation and service of this appliance. In the
Commonwealth of Massachusetts, all installation of gas
lines and gas fittings must be performed by a licensed gas
fitter or licensed plumber.
Bristol DX
GAS-FIRED DIRECT-VENT HEATER
Owner's Manual
Installation & Operating
Read This Manual in Its Entirety
Operate And Maintain This Gas Heater
According To This Instruction Manual.
SAVE THESE INSTRUCTIONS!
AVERTISSEMENT:
ASSUREZ-VOUS
SUIVRE
LES
INSTRUCTIONS
CETTE NOTICE POUR RÉDUIRE AU MINIMUM LE
RISQUE D'INCENDIE OU POUR ÉVITER TOUT
DOMMAGE MATÉERIEL, TOUTE BLESSURE OU
LA MORT.
AVERTISSEMENT: NE PAS ENTRESPOSER NI
UTILISER D'ESSENCE NI D'AUTRE VAPERURS
OU
LIQUIDES
INFLAMMABLES
VOISINAGE DE CET APPRAREIL OU DE TOUT
AUTRE APPAREIL.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où vous
vous trouvez.
Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié
installer, agence de service ou le fournisseur de gaz.
Hearthstone Quality Home Heating Products, Inc. ®
(Model 8762)
Instructions
DE
BIEN
DONNÉ
DANS
DANS
LE
Bristol DX Model 8762
Manual: 6400-40466
R: 1/4/2012

Advertisement

Table of Contents
loading

Summary of Contents for HearthStone 8762

  • Page 1 L’installation et service doit être exécuté par un qualifié fitter or licensed plumber. installer, agence de service ou le fournisseur de gaz. Hearthstone Quality Home Heating Products, Inc. ® Bristol DX Model 8762 Manual: 6400-40466 R: 1/4/2012...
  • Page 2 Intentionally Blank...
  • Page 3 Use this page to record all relevant information concerning the purchase, installation, and maintenance of your Bristol DX Model 8762 Direct -Vent heater. This information will facilitate servicing, purchase of replacement parts, and warranty claims (if necessary). Keep your original receipt in a safe place as proof of purchase.
  • Page 4: Table Of Contents

      ..............................6 AFETY NFORMATION   & F ........................ 8 ROFLAME ONTROL YSTEM EATURES   Bristol DX 8762 Model Overview ..........................8   Control Functions ..............................10   ............................... 12 PECIFICATIONS   ............................ 13 NSTALLATION REPARATION   Codes ..................................13  ...
  • Page 5: Introduction

    Bristol DX Model 8762 Introduction Congratulations on your purchase of the Bristol DX c. Six (6) blower speeds, adjustable via the Model 8762, Gas-Fired Direct-Vent heater. The remote Bristol, by Hearthstone, incorporates the latest in d. Thermostatic mode to turn on/off based direct vent gas technology, which will provide you upon room temperature.
  • Page 6: Safety Information

    Use of any components not CAN/CGA B149 Installation Code. (Installer supplied by Hearthstone on the stove voids all l’appareil selon les codes ou réglements locaux, ou, warranties. Do not substitute components. en l’absence de tells réglements, selon les Codes d’installation CAN/CGA B149.) Proper Fuel CAUTION: DO NOT USE THIS APPLIANCE IF ANY PART WAS UNDER WATER.
  • Page 7 Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 (S’ASSURER BRÛLEUR Ceramic Logs, & Burner COMPARTIMENT COMMANDES SONT If the decorative ceramic log, or burner material PROPRES. VOIR INSTRUCTIONS supplied with the Bristol is damaged or parts are D’INSTALLATION D’UTILISATION...
  • Page 8: Proflame Control System & Features

    Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 Proflame Control System & Features NOTE: OPEN DOOR UNDER THE ASH LIP AND DROP DOWN THE MODESTY PANEL FOR ACCESS TO ELECTRICAL AND GAS CONNECTIONS. Bristol DX 8762 Model Overview...
  • Page 9 Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 not available, neither the FCM nor the blower will yourself or by setting the remote control to the Smart operate. Thermostat modulation mode. Smart mode means that as the room temperature approaches the limit set...
  • Page 10: Hearthstone Quality Home Heating Products, Inc. Bristol Dx Model

    Pilot Mode Continuous Pilot (CPI): Running the Bristol 8762 in CPI mode will keep your pilot on even when the thermostat does not call for heat and when the burner is not lit. This is an advantage in cold climates or under windy conditions.
  • Page 11 Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 Remote Transmitter Figure 7 - Remote Transmitter Function Keys (remote color may differ from shown) ON/OFF Key: Controls the main burner, blower, and Mode Key: Toggles through the component to be the modulation of both.
  • Page 12: Specifications

    Tested to: ANSI Z21.88-09, CSA 2.33-09, CAN/CGA2.17-M91 Certified for Canada, CSA P.4.1-02 Approved for Mobile Home Installation (see page 7) Figure 9 - Model 8762 Dimensions ( Inches Specification INPUT RATING (Btu/hr) 0-2000 ft (0-610 m) 36,000 33,000 INPUT RATING (Btu/hr) 2000-4500 ft (610-1370 m)
  • Page 13: Installation Preparation

    The appliance when installed must be electrically Packing List connected and grounded in accordance with local 1- Bristol DX 8762 Gas-Fired Heater codes or, in the absence of local codes, with the 1- Owner’s Packet Envelope (manual, warranty card) current NFPA 70-National Electrical Code or CSA 5- Decorative Ceramic Logs (in box on pallet) C22.1-Canadian Electric Code.
  • Page 14 Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 damage is found or suspected, contact your dealer for instructions. Always use gloves and eye protection when handling Shipping Stand the decorative ceramic fire logs, and burner. Use care when handling these parts as they are fragile and subject to damage and breakage if handled roughly.
  • Page 15 Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 4. Pull forward and disengage the spring clips Firebox Access securing the top of the glass frame. See Figure 1. First, remove the top of the stove (lift off). Set 14.
  • Page 16: Clearances To Combustibles

    Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 Clearances to Combustibles Note: Ensure clearances are in accordance with local installation codes requirements of the gas supplier. Clearance to Combustibles Due to high surface temperatures, locate the unit out of traffic areas and away from furniture and draperies.
  • Page 17 Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 The corner clearance for the Bristol 8762 is 11”, measured from the edge of the top castings, to the adjacent wall. Figure 17 - Corner Clearance...
  • Page 18: Venting Information

    PROPER START UP AND IGNITION OF ALL Approved Venting Manufacturers PORTS ON THE BURNER. The Bristol Direct Vent (8762) is approved for There are two types of venting configurations installation only with the venting components approved for use with this appliance: provided by manufactures listed on this page.
  • Page 19 17/12 to 21/12 Figure 18 - Termination Cap clearances Prefabricated & Fireplace Chimney Installations The Bristol 8762 is approved for use with direct vent chimney conversion kits in masonry or prefabricated solid fuel listed chimneys. The following installation requirements must be followed: The termination must fall within the chart shown in Figure 24.
  • Page 20: Horizontal Termination

    Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 All horizontal terminations must also comply with Horizontal Termination clearance specifications adjacent The termination must fall within the area shown structures outlined in Figures 18 and 20. in Figures 18 & 20.
  • Page 21 Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 Figure 20 - Acceptable Direct Vent Terminal Vent Cap Locations A = Clearance above grade, veranda, porch, deck, H = *Not to be installed within 15 feet (4.5m) above or balcony: 12 inches (30cm) minimum.
  • Page 22: Minimum Venting Installation Instructions

    Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 thimble cover will fit properly. Screw the thimble Minimum Venting Installation cover to the wall. Instructions 1. Install the 36” pipe section onto the starter collar by fully inserting it and turning approximately ¼...
  • Page 23 Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 The restrictor consists of a sliding plate just below Restrictor Plate the venting starter collar on the top rear of the The restrictor plate is used to control excess draft if firebox.
  • Page 24 Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 Figure 24 - Venting Termination Diagram...
  • Page 25: Electrical System Information

    (ATTENTION: AU MOMENT DE L’ENTRETIEN DES COMMANDES, ÉTIQUETEZ TOUS LES FILS AVANT LE DÉBRANCHEMENT. DES ERREURS DE CÂBLAGE PEUVENT ENTRAÎUN FONCTIONNEMENT INADEQUATE ET DANGEREUX.) The proper location of wire connections is shown in the following figure. Figure 25 - Bristol 8762 Wiring Diagram...
  • Page 26: Gas Supply & Connections

    WITH THE MOST CURRENT EDITION OF THE NATIONAL FUEL GAS CODE ANSI Z223.1 (NFPA 54) OR CAN/CGA B149 INSTALLATION CODE. NFPA Code and Hearthstone require the use of a dedicated sediment trap just upstream of the unit. Damage to the valve, or other components due to the lack of a sediment trap are not covered by warranty (see figure 27).
  • Page 27: Gas Connections

    (NG) and requires conversion for use with propane (LP). You must purchase and install a propane (LP) fuel conversion kit if required for your installation. Use kit 97-56621. Contact your Hearthstone dealer. Gas Supply This appliance and its individual shutoff valve must...
  • Page 28: Log Set, & Screen Placement

    Hearthstone Quality Home Heating Products, Inc. Bristol DX Model 8762 Log Set, & Screen Placement CAUTION: FRAGILE! HANDLE LOG SET WITH CARE. ALWAYS WEAR GLOVES AND SAFETY GOGGLES WHILE HANDLING THE LOG SET. WARNING: Failure to position the burner and logs...
  • Page 29: Installation Of The Optional Screens

    Hearthstone Quality Home Heating Products, Inc. Bristol DV Model 8762 5. Place log 4 on top of logs 1 as shown. Photo 8 – Log Set Detail, Top View Photo 5 – Log 4 in Position Installation of the Optional 6.
  • Page 30: Lighting & Operation

    Pilot Light Warning installation. Hearthstone tests each unit prior to Do not attempt to light the unit with a match or by shipment, so ignition should take place without any means other than the ignition system supplied failure.
  • Page 31 Hearthstone Quality Home Heating Products, Inc. Bristol Model 8762 Some conditions cannot be corrected through air shutter adjustment; an adjustment must be made to the gas supply pressure or by changing the restriction plate setting. Qualified service personnel must perform supply line/manifold gas line pressure adjustments and restrictor plate adjustments.
  • Page 32: Daily Operation

    Hearthstone Quality Home Heating Products, Inc. Bristol Model 8762 Note: Very little movement is needed to substantially ON/REMOTE/OFF switch on the Receiver or by the change the burn and flame patterns. Some Remote Control. conditions cannot be corrected through air shutter adjustment;...
  • Page 33 Hearthstone Quality Home Heating Products, Inc. Bristol Model 8762 ON/REMOTE/OFF switch to the “OFF” To Turn off Gas and Shut Down the position. Appliance: 3. Switch the Pilot mode switch to IPI 1. Close the shut-off in the gas supply to mode.
  • Page 34: Routine Maintenance & Care

    For replacement parts, or for information about parts the firebox, set the switch to the “OFF” position, and or service, contact your local Hearthstone dealer. turn off the gas supply to the valve. When the unit is cool, remove the front panel and glass (see page 15...
  • Page 35: As Needed

    97-58620, for side Remote Transmitter Battery Replacement glass ask for kit 97-58621 from your Authorized Hearthstone Dealer. Your Bristol uses a folded flat You can easily change the Remote Transmitter fiberglass gasket to make a tight seal between the batteries by accessing the rear cover plate.
  • Page 36 Hearthstone Quality Home Heating Products, Inc. Bristol Model 8762 3. Dismount the front glass assembly by releasing Clean off as much of the hanging fiber “hairs” as the upper spring clips – then lift the frame up possible and out of the lower mounting points.
  • Page 37: Parts List

    Key: XX = Finish (e.g. 10 = Matte Black Paint) – Specify finish required when ordering parts WARNING: DO NOT SUBSTITUTE MATERIALS. FOR REPLACEMENT PARTS, OR FOR INFORMATION ABOUT PARTS OR SERVICE, CONTACT YOUR AUTHORIZED HEARTHSTONE RETAILER. For the name of the authorized retailer nearest to you, visit our website www.hearthstonestoves.com...
  • Page 38: Troubleshooting

    Hearthstone Quality Home Heating Products, Inc. Bristol Model 8762 Troubleshooting Symptom Possible Cause Corrective Action 1. Pilot will not light. A. Power supply not plugged in A. Ensure power supply is plugged in and receiving 120V and/or batteries are dead.
  • Page 39 Hearthstone Quality Home Heating Products, Inc. Bristol Model 8762 Symptom Possible Cause Corrective Action 5. Frequent pilot outage A. Pilot flame may be too low or A. Clean and/or adjust the pilot flame for maximum problem in CPI mode. blowing, (high), causing the pilot impingement on the rectification sensor.
  • Page 40: Rating Label

    Hearthstone Quality Home Heating Products, Inc. Bristol Model 8762 Rating Label...
  • Page 41: Warranty Registration

    Warranty Registration Form, which is enclosed in the Gas Stove warranty packet, to the following address: Hearthstone Quality Home Heating Products, Inc. Warranty Department 317 Stafford Avenue Morrisville, VT 05661 NOTE: SENDING IN THE SIGNED WARRANTY REGISTRATION FORM IS NOT REQUIRED AS A CONDITION OF WARRANTY COVERAGE OR HEARTHSTONE’S PERFORMANCE.

This manual is also suitable for:

Bristol dx 8762

Table of Contents