HearthStone Quality Home Heating Products Inc
6.
Gently slide the medium length of
the "half" logs (4) onto pin E as shown
below.
7.
Gently slide the long unbroken log
(5) onto pins C and D as shown below.
8.
Spread evenly across the front portion of
the Pan Burner, one layer high, the Charcoal
Embers. You may or may not need to use all of
Embers. Keep the rest for use
the Charcoal
in the future.
Locate and open the bag of rock
wool. Pull apart small pieces of the wool and
sprinkle over the Charcoal Embers randomly.
This wool will glow once the unit is running.
SANTA FE 1 Gas-Fired Direct Vent heater
Figure 12
9.
With a 1/8" hex head wrench, use the
bolt to fasten the door to the firebox. Make
sure the door is properly secured to the firebox
before lighting the unit. Be careful not to chip
the enamel when fastening the door.
R
L
EMOVAL OF
OG
Caution! Log set and charcoal embers
will retain heat and can be very hot, if
previously lit! Allow at least 1 hour
after pilot light is turned off before
handling.
To remove the log set, follow the
Installation of Log Set instructions in the
reverse order.
Caution!
charcoal embers with care.
L
U
IGHTING THE
S
F
MOKE AND
UMES
When lit for the first time, the Santa Fe will emit
some smoke and odors. This is normal "off-
gassing" of the paints and oils used in the
manufacturing, and assembly of the unit. Open
windows to vent the room if necessary. The off
gassing and fumes will subside after the first 10
to 20 minutes of operation.
Once the Santa Fe is set in place and connected
as described previously, the unit is ready to be lit
for the first time. Hearthstone tests each Santa
Fe before shipment, so ignition should take
place without failure.