Table 6-5. Machine Configuration Programming Information Software Version P6.1 to Present
Configuration Label/
Digit
GEN SET/WELDER:
12
GEN SET CUTOUT:
13*
* Only visible if Gen Set /
Welder Menu selection is
not 0.
H & T LIGHTS:
14
CABLE SWITCH:
15*
* Only visible under certain
model selections.
* Certain market and
model selections will alter
the default setting.
LOAD SYSTEM:
16*
* Only visible under certain
market selections.
* Certain market selections
will limit load system
options or alter default set-
ting.
3121201
Number
0
NO: No generator installed.
1
BELT DRIVE: Belt driven setup.
0
MOTION ENABLED: Motion enabled when generator is ON.
1
MOTION CUTOUT: Motion cutout in platform mode only.
0
NO: No head and tail lights installed.
1
YES: Head and tail lights installed.
0
NO: No broken cable switch installed.
1
YES: Broken cable switch installed.
0
NO: No load sensor installed.
1
WARN ONLY: Functions in creep, overload lamp lit, platform alarm beeps (5 sec ON, 2
sec OFF).
2
CUTOUT PLATFORM: All functions cutout, overload lamp lit, platform alarm beeps (5
sec ON, 2 sec OFF).
3
CUTOUT ALL: All functions cutout, flash overload light (500mS on, 500mS off), platform
alarm beeps (5 sec ON, 2 sec OFF).
4
SPECIAL 1: Functions in creep, overload lamp lit, disables main telescope out & main lift
up, platform alarm beeps (5 sec ON, 2 sec OFF).
SECTION 6 - JLG CONTROL SYSTEM
Description
– JLG Lift –
Default
Number
0
0
0
0
0
6-43