SECTION 6 - JLG CONTROL SYSTEM
Table 6-4. Machine Configuration Programming Information Software Version P5.3 to P6.1
Configuration Label/
Digit
GEN SET CUTOUT:
13*
* Only visible if Gen Set /
Welder Menu selection is
not 0.
H & T LIGHTS:
14
CABLE SWITCH:
15*
* Only visible under certain
model selections.
* Certain market and
model selections will alter
the default setting.
LOAD SYSTEM:
16*
* Only visible under certain
market selections.
* Certain market selections
will limit load system
options or alter default set-
ting.
LOAD SENSOR:
17*
* Only visible if Load Sen-
sor Menu selection is not 0
and under certain market
selections.
* Certain market selections
will limit load sensor
options.
6-38
Number
0
MOTION ENABLED: Motion enabled when generator is ON.
1
MOTION CUTOUT: Motion cutout in platform mode only.
0
NO: No head and tail lights installed.
1
YES: Head and tail lights installed.
0
NO: No broken cable switch installed.
1
YES: Broken cable switch installed.
0
NO: No load sensor installed.
1
WARN ONLY: Functions in creep, overload lamp lit, platform alarm beeps (5 sec ON, 2
sec OFF).
2
CUTOUT PLATFORM: All functions cutout, overload lamp lit, platform alarm beeps (5
sec ON, 2 sec OFF).
3
CUTOUT ALL: All functions cutout, flash overload light (500mS on, 500mS off), platform
alarm beeps (5 sec ON, 2 sec OFF).
4
SPECIAL 1: Functions in creep, overload lamp lit, disables main telescope out & main lift
up, platform alarm beeps (5 sec ON, 2 sec OFF).
0
1 ON ROTATOR: Use the on-board load sensor for all models except those which use the
Leveling Platform Module.
1
4 UNDER PLATFORM: Use the EIM for load sensing.
Description
– JLG Lift –
Default
Number
0
0
0
0
1
3121201