Network Alarm: Check this box to send out a network alarm to a client PC when this event occurs. (This feature requires
PowerCon software on the client PC and proper settings for the Alarm Server in the Network Setup menu; see the Alarm
Server section for more information.)
Stop Recording: Check this box to let the DVR stop recording when its HD's temperature goes over the selected limit.
Temp. Warning Limit: This sets the trigger temperature for HD Temperature events. Selectable limits range from 50 ° C to
70 ° C.
Alarm Output: Click on one of the numbers in the dropdown box to let the DVR transmit a signal through the alarm output
with the same number, if this event occurs. Selecting "None" would disable this reaction.
Output Type: If an Alarm Output reaction is configured the type of alarm output will be Transparent and cannot be
changed. This means that the alarm output signal would continue as long as the alarm condition is active.
HD Failure:
Log: Check this box to record HD Failure events in the
log.
Buzzer: Check this box to activate the DVR's buzzer if no
hard drive is detected on system startup.
Email Notify: Check this box to enable email notification
when the selected event occurs. This requires that valid
email settings have been entered in the Network Setting >
Email setup screen.
Network Alarm: Check this box to send out a network
alarm to a client PC when this event occurs. (This feature
requires PowerCon software on the client PC and proper
settings for the Alarm Server in the Network Setup menu; see the Alarm Server section for more information.)
Alarm Output: Click on one of the numbers in the dropdown box to let the DVR transmit a signal through the alarm output
with the same number, if this event occurs. Selecting "None" would disable this reaction.
Output Type: If an Alarm Output reaction is configured, the type of alarm output will be Transparent and cannot be
changed. This means that the alarm output signal would continue as long as the alarm condition is active.
HD Full:
Log: Check this box to record HD Full events in the log.
Buzzer: Check box to activate the buzzer when the hard
drive is full (recommended if the Record Overwrite function
is disabled in the Record & Play > Record menu).
Email Notify: Check this box to enable email notification
when the selected event occurs. This requires that valid
email settings have been entered in the Network Setting >
Email setup screen.
Network Alarm: Check this box to send out a network
alarm to a client PC when this event occurs. (This feature
requires PowerCon software on the client PC and proper
settings for the Alarm Server in the Network Setup menu;