feed will be displayed in full screen on the Main monitor.
Call Monitor: Call-monitor display reaction options when a motion event occurs.
No change: No change on the call-monitor display.
Full screen: If this camera experiences a motion event, its feed will be displayed in full screen on the Call monitor.
Pre-alarm Record: Check this box to add to the motion-event recording (recorded on the hard disk) footage from 10
seconds before the motion event. (The default minimum pre/post-recording buffer is around 4 seconds before and 2
seconds after the alarm/event starts and stops. This pre-alarm recording's frame rate will follow the "Normal" frame rate
settings.)
Buzzer: Check this box to let a motion-event trigger activate the DVR's buzzer.
Email Notify: Check this box to send email notification when a motion event is detected. Email operation requires that valid
email settings have been entered in the Network Setting/Email setup screen. (See the Email section for more information.)
Network Alarm: Check this box to send out a network alarm to a client PC when a motion event occurs. (This feature
requires PowerCon software to be installed on the client PC and proper settings for the Alarm Server in the Network Setup
menu; see the Alarm Server section for more information.)
Auto Lock: Check this box to have all events recorded in a write-protected segment of the Hard Disk. (The DVR will lock a
period of time when the alarm occurs, the length of time will depend on the DVR's configuration.)
Alarm Output: Selecting "None" will leave this function disabled. Selecting one of the four numbers will instruct the DVR to
transmit a signal through the alarm output relay marked with the same number (at the back of the DVR) when a motion
event occurs on this camera channel. This will only work if a device has been connected to the relevant output relay.
Output Type: If an Alarm Output has been selected above this setting, this setting will decide how that Output is transmitted
when a motion event occurs.
Timeout: The alarm output lasts for a set period of time. If this option is selected, a field will appear under this field for
setting the period duration. Setting options are 1~150 seconds.
Permanent: The alarm will remain on until the user presses the "Enter" key on the front panel, or resets the alarm
configuration.
Transparent: The alarm output continues as long as motion is detected.
Trans+Timeout: The alarm output continues as long as motion is detected, then it continues for the set time period.
Timeout Duration: This period can be from 1 to 150 seconds.
Edit Motion Grid: Press this button to edit the motion grid (see the image on the right). Click on the video area to see the
grid. Motion Detection areas are colored green.
Sensitivity: Set the threshold value for sensitivity within the
grids. Select from 1 (lowest) to 10 (highest).
Min Area: To avoid motion events being triggered by small
objects, this number defines how many grid blocks have to
detect (exceed the sensitivity threshold) movement before
a motion event is triggered. Select a value between 1
(default) and 5 grid blocks.
Motion Delay: Set
Preview: Preview the motion grid.