ESIE09-08

5. Other Control

Heating Operation Prohibition

5.1
For more details see chapter of settings.
5.2

Inverter Fan Control (Switch Box Fan)

5.3

Crankcase Heater

Function
If the ambient temperature becomes higher than (24°C + value of setting [9-02]) no space
heating is possible
Heating for domestic hot water is possible till 35°C ambient temperature.
Compressor ON
Tfin>50°C
Cooling fan OFF
Tfin<30°C
Compressor OFF
Tdi error
OR
AND
Crankcase heater OFF
OR
Cooling fan ON
Compressor OFF
Tdi<70°C
Crankcase heater ON
Tdi>75°C
Compressor ON