B.1

Watchdog Timer Programming

--------------------------------------------------------------
---------------------
Enter the extended function mode, interruptible double-write
--------------------------------------------------------------
---------------------
MOV DX,2EH
MOV AL,87H
OUT DX,AL
OUT DX,AL
--------------------------------------------------------------
---------------
Configured logical device 8, configuration register CRF6
--------------------------------------------------------------
---------------
MOV DX,2EH
MOV AL,2BH
OUT DX,AL
MOV DX,2FH
IN AL,DX
AND AL.OEFH; Setbit 4=0 Pin 89=WDTO
OUT DX,AL
MOV DX,2EH
MOV AL,07H; point to Logical Device Number Reg.
OUT DX,AL
MOV DX,2FH
MOV AL,08H; select logical device 8
OUT DX,AL;
MOV DX,2EH
MOV AL,30H;Set watch dog activate or inactivate
OUT DX,AL
MOV DX,2FH
MOV AL,01H; 01:activate 00:inactivate
OUT DX,AL;
MOV DX,2EH
MOV AL,F5H; Setting counter unit is second
OUT DX,AL
MOV DX,2FH
MOV AL,00H
OUT DX,AL;
MOV DX,2EH
MOV AL,F6H
OUT DX,AL
MOV DX,2FH
MOV AL,05H; Set 5 seconds
ECU-4784 User Manual