To program:
pick up the handset
- dialling tone
dial the access code 333320 to store password related to external line no.1
dial a chosen 4-digit password (from 0000 to 9999). Always dial a 4-digit number
wait for the acknowledgement tone and hang up.
Repeat the above procedure with a different password and access code for external line 2
(only FT208P).
Example: if the number below has been dialled:
3333200100
the actuator cards installed in the PABX can be activated by making a
call to external line 1 and dialling password 0100.
Operation
select the subscriber number to which the PABX is connected from an external telephone
- Public Exchange call control tone
wait for the D.I.S.A. post-dialling tone
dial 7
dial the password programmed for the specific external line
dial the number of the relay to be activated
1 relay 1
2 relay 2
3 relay 3
4 relay 4
select the relay action
(only for relays 2, 3 and 4.
Relay 1 is activated for 3
seconds)
0 the relay is deactivated
1 the relay is activated
2 the relay is activated for 3 seconds
acknowledgement tone.
Examples: make the connection with the user's number and dial 7010032: relay 3 is
activated for 3 seconds, being 0100 the password related to external line 1 (see example
above). To enable relay 1, dial 7 + the password code + 1. Relay 1 can only be activated
for about 3 seconds.
Note
In case of incorrect dialling , of wrong password or no password within 5 seconds, the call
is automatically sent to all extensions enabled to receive external calls.