2.7
INSTALLATION OF THE GAS SUPPLY (INTO STUDDED WALL OR
EXISTING CHIMNEY BREAST)
Before installing the combustion chamber, decide from which side or if a rear
connection to the gas supply is required. Plan the pipe run to enter the firebox
from the left, right or rear and connect to the inlet elbow. See Fig. 11, 12 & 13
below.
Note : Before breaking into the gas supply a gas tightness test should be
carried out to establish that the existing pipework is sound.
Fig. 11
Ensure if
bringing
gas
supply
through
Combustion Chamber
side or rear
of a
chimney
breast that
Fig. 12
the pipe is
sleeved
and sealed
with a
suitable
flexible, non
setting
compound
Fig. 13
IMPORTANT NOTE : THE GAS INLET APERTURES THAT ARE NOT
USED IN THE FIREBOX SHOULD BE TAPED UP USING THE LENGTH
OF ALUMINIMUM FOIL TAPE SUPPLIED. FAILURE TO DO SO MAY
LEAD TO FLAME REVERSAL AND DAMAGE OF THE CONTROLS. BFM
EUROPE WILL NOT ACCEPT GUARANTEE CLAIMS THAT ARE A DIRECT
RESULT OF THE INLET APERTURES NOT BEING CORRECTLY SEALED.
Gas Supply entering from Rear of Combustion Chamber
Combustion Chamber
Combustion Chamber
14
Gas Supply entering from R/H/S