Gas Tightness And Inlet Pressure; Fitting The "Pure" Fascia - Flavel Pure FPRG**RN2 Installation And Maintenance Instructions Manual

Decorative fuel effect gas fire
Hide thumbs Also See for Pure FPRG**RN2:
Table of Contents

Advertisement

2.8

GAS TIGHTNESS AND INLET PRESSURE

a)
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
b)
Turn on the main gas supply and carry out a gas tightness test.
c)
Depress both the round buttons on the handset. The fire will then
commence its ignition sequence and will light to high. See page 17 / 18
for full details of the operating method for the fire.
d)
Check that the gas pressure is 20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-
0.4 in w.g.)
e)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.
IMPORTANT NOTE - IF THE APPLIANCE HAS BEEN INSTALLED WITHOUT
A FLUE LINER
ENSURE THE LABEL THAT SPECIFIES THE PRODUCT HAS BEEN
INSTALLED WITHOUT A FLUE LINER IS NOW CORRECTLY FILLED IN
WITH THE INSTALLERS DETAILS. THE LABEL IS FITTED TO THE GAS
INLET ELBOW AND MUST BE LEFT IN POSITION FOLLOWING
COMMISIONING OF THE PRODUCT.
2.9

FITTING THE "PURE" FASCIA

a)
The "Pure " fascia is fitted to the product by hooking the top edge of the
fascia over the mounting brackets as shown in Fig. 14 below, then
securing with magnets at the bottom.
Fig. 14
15
Hook "Pure"
fascia onto top
mounting brackets