2.6
FITTING THE SPIGOT OUTLET HOOD / DEBRIS DEFLECTOR AND
HEAT BAFFLE (INSTALLING WITHOUT FLUE LINER)
If fitting without a flue liner, into a chimney that is has had it's soundness assured
by testing, and is less than 10 metres in height on an external wall or 12 metres on
an internal wall, then the appliance can be fitted with the flue spigot outlet hood as
supplied. The complete spigot outlet / debris deflector assembly and heat baffle
can be fitted / removed from inside the product by removal of the 12 retaining
screws, as shown below in fig. 9.
Fig. 9
REAR
Spigot hood
retained by 12
off M6 screws
FRONT
Under no circumstances can the flue debris spacer brackets be removed or
manipulated from the spigot outlet hood. These brackets are required to ensure
that the minimum flue debris collection volume behind the product is available, as
shown below in Fig. 10. Removal or manipulation of the position of these
brackets could cause a flue blockage. If the required depth is not available,
the chimney must be lined throughout it's length.
Fig. 10
VOID FOR FLUE DEBRIS COLLECTION BEHIND FIREBOX
Minimum 385mm
Spigot Opening
Viewed from inside spigot hood
Firebox
Heat Baffle to be secured to front underside of
collection hood via two central fixing screws
13
Flue Debris
Spacer Brackets
Depth Required
385mm
Minimum