Checking For Clearance Of Combustion; Products - Flavel Pure FPRG**RN2 Installation And Maintenance Instructions Manual

Decorative fuel effect gas fire
Hide thumbs Also See for Pure FPRG**RN2:
Table of Contents

Advertisement

3.2
CHECKING FOR CLEARANCE OF COMBUSTION PRODUCTS
a)
Close all doors and windows in the room.
b)
Light the fire and allow to run for approximately 5 minutes on high
position.
c)
After approximately 5 minutes hold a smoke match as shown at the
lower front edge of the draught divereter, as shown below in Fig. 18
It is recommended that a suitable smoke match holder is used when
checking for clearance of combustion products. All smoke generated
should be drawn back into the flue. If slight spillage occurs or if in
doubt, repeat the test after a further 5-10 minutes.
d)
If spillage persists, the flue is not functioning correctly and a fault exists.
If, after investigation the fault cannot be traced and rectified, the fire
must be disconnected from the gas supply and expert advice obtained.
e)
If there is an extractor fan fitted any where in the vicinity of the
appliance, the spillage test should be repeated with the fan running on
maximum and all interconnecting doors open.
f)
After ensuring that the fire is safe to use it should be left on high
position to fully warm up. During this time a slight odour may be
noticed, this is due to the "newness" of the fire and will soon disappear.
Finally, hand the Installation and Maintenance Instructions and the
Users Instructions over to the customer and explain the operation of the
fire.
Fig. 18
NOTE : If the product has been installed without the use of a flue
liner and a spillage problem persists, it may be necessary to line the
chimney.
Smoke Match Position - 25mm below and inside the
lower edge at the center of the opening in the glass
frame.