Gas Soundness And Burner Pressure - Flavel Warwick FIRC14MN Installation And Maintenance Instructions Manual

Coal effect gas fire
Table of Contents

Advertisement

2.3
GAS SOUNDNESS AND INLET PRESSURE
a)
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
b)
Turn on the main gas supply and carry out a gas soundness test.
c)
Depress the control knob and turn anti-clockwise to the position marked
pilot. Hold in the control knob for a few seconds to purge the pipe work
then press the igniter button. The burner should light, continue to hold
the control knob for a few seconds then turn to the full-on position.
d)
Check that the gas pressure is 20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-
0.4 in w.g.).
e)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas soundness with the
appliance turned on using a suitable leak detection fluid or detector.
Supplied By www.heating spares.co Tel. 0161 620 6677
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Warwick firc26mn

Table of Contents