Typical Moisture Measurement And Documentation Procedure; General; Procedure - FLIR Exx Series User Manual

Hide thumbs Also See for Exx Series:
Table of Contents

Advertisement

17
Fetching data from external Extech meters
5. Do one of the following:
• To preview an image, push the Preview/Save button. At this stage, you can add
additional values. To do so, take a new measurement with the meter and select
Add on the infrared camera screen.
• To save an image without previewing, push and hold down the Preview/Save
button.
• (Dependent on camera model) To add a value to a recalled image, turn on the me-
ter after you have recalled the image, then select Add on the infrared camera
screen. A maximum of eight values can be added, but note that some values are
broken into two lines.
6. Click Close or Save (depending on camera model).

17.6 Typical moisture measurement and documentation procedure

17.6.1 General

The following procedure can form the basis for other procedures using Extech meters
and infrared cameras.

17.6.2 Procedure

Follow this procedure:
1. Use the infrared camera to identify any potential damp areas behind walls and
ceilings.
2. Use the moisture meter to measure the moisture levels at various suspect locations
that may have been found.
3. When a spot of particular interest is located, store the moisture reading in the mois-
ture meter's memory and identify the measurement spot with a handprint or other
thermal identifying marker.
4. Recall the reading from the meter memory. The moisture meter will now continuously
transmit this reading to the infrared camera.
5. Use the camera to take a thermal image of the area with the identifying marker. The
stored data from the moisture meter will also be saved on the image.