16
. ELECTRICAL EQUIPMENT
REGULATOR/RECTIFIER
INSPECTION
Remove the front cover. ( 13-4)
Disconnect the regulator/rectifier wire
coupler and remove the nut to remove the
regulator/rectifier.
Measure the resistances between the
terminals.
Replace the regulator/rectifier if the
readings are not within the specifications in
the table below.
• Due to the semiconductor in circuit, it
is necessary to use a specified tester
for accurate testing.
improper tester in an improper range
may give false readings.
2-Stroke
Probe⊕
A (R)
B (W)
Probe(-)
A (R)
B (W)
3-10KΩ
C (Y)
D (G)
4-Stroke
Probe⊕
A (R)
B (W)
Probe(-)
A (R)
3-4MΩ
B (W)
6-8MΩ
C (Y)
D (G)
Use of an
C (Y)
D (G)
33-35KΩ
33-35KΩ
C (Y)
D (G)
14-15MΩ
14-15MΩ
Regulator/Rectifier
A (Red)
B (White)
VITALITY 50
Nut
Coupler
C (Yellow)
D (Green)
16-10