16
. ELECTRICAL EQUIPMENT
VITALITY 50
STARTER RELAY INSPECTION
Starter Relay
Remove the met-in box. ( 13-5)
Disconnect the starter relay coupler and
then remove the starter relay.
Connect the starter relay green/yellow
Red
Starter Relay (2-Stroke)
Yellow/Red
terminal to the 12V battery positive (+)
terminal and the relay yellow/red terminal
to the battery negative (-) terminal. Check
for continuity between the starter relay red
and red/white terminals. The relay is normal
if there is continuity.
Green/Yellow
Red/White
Starter Relay (4-Stroke)
16-18