Diagnostics - Printer Setup

Defaults

The following printer settings are used to determine whether U.S. or
non-U.S. factory defaults should be used:
= U.S. *
= Non U.S.
Light Quantity
Cyan
Magenta
Yellow
Black
Range = 0 to 45
If you replace one or more of the printheads, or the EEPROM for the
engine controller, the Light Quantity value must be set to the value
that is marked on the printhead. To set this value:
1. Select Diagnostic Mode.
2. Select Printer Setup.
3. Select Light Quantity and enter the value from the label on the
printhead.