Introduction To Building Thermography; Important Note; Typical Field Investigations; Guidelines - FLIR InfraCAM User Manual

Hide thumbs Also See for InfraCAM:
Table of Contents

Advertisement

12
Introduction to building
thermography
12.1

Important note

All camera functions and features that are described in this section may not be sup-
ported by your particular camera configuration.
12.2

Typical field investigations

12.2.1

Guidelines

As will be noted in subsequent sections there are a number of general guidelines the
user should take heed of when carrying out building thermography inspection. This
section gives a summary of these guidelines.
12.2.1.1

General guidelines

The emissivity of the majority of building materials fall between 0.85 and 0.95.
Setting the emissivity value in the camera to 0.90 can be regarded as a good
starting point.
An infrared inspection alone should never be used as a decision point for further
actions. Always verify suspicions and findings using other methods, such as con-
struction drawings, moisture meters, humidity & temperature datalogging, tracer
gas testing etc.
Change level and span to thermally tune the infrared image and reveal more details.
The figure below shows the difference between a thermally untuned and a thermally
tuned infrared image.
10552103;a2
Figure 12.1 LEFT: A thermally untuned infrared image; RIGHT: A thermally tuned infrared image, after
having changed level and span.
Publ. No. 1558299 Rev. a200 – ENGLISH (EN) – February 12, 2007