12 – Introduction to building thermography
12.2.7.3
This section includes a few typical infrared images of details of building structures
where air infiltration has occurred.
Infrared image
10552703;a1
10552803;a1
10552903;a1
12
88
Commented infrared images
Comment
Air infiltration from behind a skirting strip. Note the
typical ray pattern.
Air infiltration from behind a skirting strip. Note the
typical ray pattern.
The white area to the left is a radiator.
Air infiltration from behind a skirting strip. Note the
typical ray pattern.
Publ. No. 1558299 Rev. a200 – ENGLISH (EN) – February 12, 2007