HYOSUNG Aquil GV650 Service Manual page 66

Table of Contents

Advertisement

3-23 ENGINE
● Inspect the tappet for wear and scratch.
If modification or scratch is present, replace the tap-
pet.
● When you checked the valve clearance, if the valve
clearance is wide please replace the present shim
into thick one, if the valve clearance is narrow please
replace the present shim into thin shim.
(Refer to page 8-31 ∙ 32)
▣ SHIM KIND
There are 41 kinds of shim which thickness is increased
by each 0.025 mm from 1.20 mm to 2.20 mm.
◉ VALVE HEAD RADIAL RUNOUT
Place a dial gauge as shown and measure valve
head radial runout.
If the service limit is exceeded, replace the valve.
Valve head radial
runout
Dial gauge : 09900-20606
Magnetic stand : 09900-20701
V-block : 09900-21304
◉ VALVE GUIDE-VALVE STEM
CLEARANCE
Measure the clearance in the valve guide-valve stem, by
rigging up the dial gauge as shown. If the clearance
is measured exceeds the limit specified below, then
determine whether the valve or the guide should be
replaced to reduce the clearance to within the standard
range :
Valve guide-valve stem clearance
IN.
EX.
Dial gauge : 09900-20606
Magnetic stand : 09900-20701
◉ VALVE STEM DIAMETER
Measure the valve stem outside diameter.
If the diameter measured exceeds the standard, replace
the valve.
Valve stem diameter
IN.
4.465~4.480 mm (0.1758~0.1764 in)
EX.
4.455~4.470 mm (0.1754~0.1760 in)
Micrometer(0~25 mm) : 09900-20201
Service limit
0.03 mm (0.0012 in)
Standard
0.020~0.047 mm
(0.0008~0.0019 in)
0.030~0.057 mm
(0.0012~0.0022 in)
Standard

Hide quick links: