▣ REGULATOR / RECTIFIER
● Disconnect the coupler.
● Using the pocket tester (× 1 ㏁ range), measure the
resistance between the terminals in the following
table.
If the resistance checked is incorrect, replace the regu
lator / rectifier.
� � Tester probe
3�4 ㏁
3�4 ㏁
3�4 ㏁
3�4 ㏁
1�2 ㏁
1�2 ㏁
1�2 ㏁
1�2 ㏁
Pocket tester : 09900 - 25002
Unit : ㏁
3�4 ㏁
1�2 ㏁
1�2 ㏁
3�4 ㏁
1�2 ㏁
1�2 ㏁
1�2 ㏁
1�2 ㏁
1�2 ㏁
1�2 ㏁
32 ㏀
32 ㏀
ELECTRICAL SYSTEM 6-10