Always perform pre-power troubleshooting before applying power to unit (see Section 8).

9-8. Main Control Board PC1 Test Point Values (Eff. w/LE411272)

Receptacle
RC1
RC2
RC3
Millermatic 350
PC1 Voltage Readings
Pin
1
+2 to 20.5 volts DC with respect to RC1-4
2
+24 volts DC when input voltage drops to less than 15% of highest input line with respect to
RC1-5
3
24 volts AC when switch S1 is On with respect to RC1-7
4
+2 to 20.5 volts DC to motor with respect to RC1-1
5
+24 volts DC when input voltage drops to less than 15% of highest input line with respect to RC1-2
6
+34 volts DC when gun trigger is closed, 0 volts when gun trigger is open with respect to RC1-8
7
24 volts AC to contactor W when switch S1 is On with respect to RC1-3
8
+34 volts DC when gun trigger is closed, 0 volts when gun trigger is open with respect to RC1-6
1
18 volts AC input with respect to RC2-3 or RC2-4
2
Not used
3
18.7 volts AC input with respect to RC2-1
4
18.7 volts AC input with respect to RC2-1
5
Not used
6
+1 volt DC input per 100 amps weld output with respect to RC2-10
7
−15 volts DC input with respect to RC2-10
8
+15 volts DC input with respect to RC2-10
9
Not used
10
Circuit common
11
Circuit board ground
12
25.3 volts AC input with respect to RC2-13 or RC2-14
13
25.3 volts AC input with respect to RC2-12
14
25.3 volts AC input with respect to RC2-12
1
+335 volts DC, negative side of capacitor C4
2
Not used
3
Not used
4
+335 volts DC, positive side of capacitor C4
5
Not used
6
Not used
a) Tolerance −
10% unless specified
b) Reference − to circuit common
(chassis ground) unless noted
c) Triggered − means gun trigger is
pressed
Values
TM-1327 Page 61