Always perform pre-power troubleshooting before applying power to unit (see Section 8).
9-3. Troubleshooting Circuit Diagram For 200/230/460/575 V Models (Continued)
Voltage Readings
a)
Tolerance −
10% unless specified
b)
Reference − to circuit common
(chassis ground) unless noted
V1
24 volts AC with switch S1 in
On position
V2
+34 volts DC when gun
trigger is closed, 0 volts when
gun trigger is open
V3
approximately +2 to +20.5
volts DC from min to max of
IPM command signal with
gun trigger closed
V4
+1 volt DC per 100 amps of
command signal with respect
to RC2-10
V5
−15 volts DC with respect to
RC2-10
V6
+15 volts DC with respect to
RC2-10
V7
approximately +2.5 to 22
volts DC from min to max of
IPM command signal with
gun trigger closed when
optional gun is attached to
unit (see Section 4-4 or 4-5)
V8
+76 to +90 volts DC
open-circuit voltage
V9
+24 volts DC when
fan-on-demand circuit is on;
0 volts when circuit is off
TM-1327 Page 54
Resistance Values
a)
Tolerance −
10% unless specified
b)
Turn Off unit and disconnect input
power before checking resistance
R1
30k ohms at 25 C
R2
30k ohms at 25 C
Millermatic 350