Set Up Push Motor Torque (Sup) - Miller Millermatic 350P Technical Manual

Arc welding power source and wire feeder
Hide thumbs Also See for Millermatic 350P:
Table of Contents

Advertisement

.
Welding wire birdnesting at the welding power source drive rolls may occur if this value is set too high.

6-11. Set Up Push Motor Torque (SUP)

1
1
Setup Button
2
Left Knob
3
Left Display
4
Right Knob
5
Right Display
6
Arc Control Button
While
at
main
welding
simultaneously press Setup and Arc Control
Millermatic 350
3
2
buttons, and release buttons.
Rotate the left knob counterclockwise
(CCW) to find the SUP value, and rotate the
right knob to change the setting.
The following items can be adjusted by
rotating the left knob counterclockwise
(CCW):
Set up Push Motor Torque (SUP) − This
screen,
feature is only active when a push/pull gun
is connected to the welding power source.
5
4
The (SUP)
setting
over-torque limit of the push motor inside
the welding power source. The range is
100-250 and the default value is 130.
Increasing this setting will increase the
over-torque limit and speed up the remote
wire feed speed motor.
.
If XR - AlumaPro push/pull gun has a
listed SUP value, set the power source
to match the SUP value.
6
Ref. 213 935-A
will
adjust the
TM-1327 Page 37