User Interface Board Pc3 Test Point Values - Miller Millermatic 350P Technical Manual

Arc welding power source and wire feeder
Hide thumbs Also See for Millermatic 350P:
Table of Contents

Advertisement

Always perform pre-power troubleshooting before applying power to unit (see Section 8).

9-12. User Interface Board PC3 Test Point Values

Receptacle
J3
JP5
JP6
Millermatic 350
PC3 Voltage Readings
Pin
1
Not used
2
+ Voltage feedback
3
Not used
4
− Voltage feedback
1
+5 volts DC with respect to JP5-3
2
+5 volts DC with respect to JP5-3
3
dgrnd
4
dgrnd
5
+25 volts DC with respect to JP5-3
1
+33.1 volts DC with gun trigger open, 0 volts with gun trigger closed
2
+33.1 volts DC with gun trigger open, 0 volts with gun trigger closed
3
+33.1 volts DC with gun trigger open, 0 volts with gun trigger closed
4
+33.1 volts DC with gun trigger open, 0 volts with gun trigger closed
5
Gun select with respect to JP6-8
6
+5 volts DC for 50 IPM wire feed speed, 0 volts for 800 IPM wire feed speed
7
+5 volts DC for 50 IPM wire feed speed, 0 volts for 800 IPM wire feed speed
8
Gun select with respect to JP6-5
a) Tolerance −
10% unless specified
b) Reference − to circuit common
(chassis ground) unless noted
c) Triggered − means gun trigger is
pressed
Values
TM-1327 Page 67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Millermatic 350

Table of Contents