6-3. Timers

1
2
3
4
5
6
To enter the TIMERS (5) menu depress the
SETUP (6) button 4 times or until the
TIMERS light (5) is illuminated.
Items that can be adjusted in this menu are:
R‐IN
Run-in speed (
) − The speed of the
wire prior to the welding arc being struck.
This setting is a percentage of the Wire
Feed Speed the unit is set to for welding.
Programming value ranges from 25-150.
PRE
Preflow (
) − The amount of time that the
shielding gas will flow after the trigger is
TM-1327 Page 28
8
depressed and before the welding arc will
be allowed to be active. Range of setting is
from 0-5 seconds.
POST
Postflow (
) − The amount of time that
the shielding gas will flow after the arc has
been shut off. Range of setting is 0-10
seconds.
SPOT
Spot Timer (
) − The amount of time
that the arc will be active before it shuts off
automatically. Range of setting is from
0-120 seconds. Spot timer is reset upon re-
lease of welding gun trigger.
9
DISP
Display (
) − Allows the Wire Speed
display to show actual welding amperage
while arc is active and for 5 seconds after
arc is shut off. Setting is either AMPS or
WFS for standard Wire Feed Speed.
Once in the TIMERS (5) menu, rotate the
left knob (8) to find a particular item, and ro-
tate the right knob (9) to change setting or
status.
Depress SETUP (6) button to get out of
TIMERS (5) menu and to enter welding
mode.
7
Ref. 213 935-A