Always perform pre-power troubleshooting before applying power to unit (see Section 8).

9-10. Interconnect Board PC2 Test Point Values

Receptacle
RC2
Millermatic 350
PC2 Voltage Readings
Pin
1
Input voltage with respect to RC2-3
2
Not used
3
Input voltage with respect to RC2-1
4
Not used
5
Not used
6
Not used
7
+335 volts DC positive side of capacitor C4
8
Not used
9
+335 volts DC negative side of capacitor C4
a) Tolerance −
10% unless specified
b) Reference − to circuit common
(chassis ground) unless noted
c) Triggered − means gun trigger is
pressed
Values
TM-1327 Page 65