Cisco SPA2102 Administration Manual page 63

Analog telephone adapters
Hide thumbs Also See for SPA2102:
Table of Contents

Advertisement

Configuring Dial Plans
NOTE
Cisco Small Business ATA Administration Guide
Interdigit Long Timer (Incomplete Entry Timer)
You can think of this timer as the “incomplete entry” timer. This timer measures the
interval between dialed digits. It applies as long as the dialed digits do not match
any digit sequences in the dial plan. Unless the user enters another digit within the
specified number of seconds, the entry is evaluated as incomplete, and the call is
rejected. The default value is 10 seconds.
This section explains how to edit a timer as part of a dial plan. Alternatively, you can
modify the Control Timer that controls the default interdigit timers for all calls. See
“Resetting the Control Timers,” on page
Syntax for the Interdigit Long Timer
SYNTAX: :s,
s: The number of seconds; if no number is entered after
5 seconds applies.
Note that the timer sequence appears to the left of the initial parenthesis for the
dial plan.
Example for the Interdigit Long Timer
EXAMPLE:
L:15,
This dial plan allows the user to pause for up to 15 seconds between digits
L:15,
before the Interdigit Long Timer expires. This setting is especially helpful to users
such as sales people, who are reading the numbers from business cards and other
printed materials while dialing.
Interdigit Short Timer (Complete Entry Timer)
You can think of this timer as the “complete entry” timer. This timer measures the
interval between dialed digits. It applies when the dialed digits match at least one
digit sequence in the dial plan. Unless the user enters another digit within the
specified number of seconds, the entry is evaluated. If it is valid, the call proceeds.
If it is invalid, the call is rejected. The default value is 3 seconds.
65.
, the default timer of
4
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spa8000Pap2tSpa8800Spa3102

Table of Contents