ATA Voice Field Reference
Regional page
Cisco Small Business ATA Administration Guide
Call Back Delay
VMWI Refresh Intvl
Interdigit Long
Timer
Interdigit Short
Timer
CPC Delay
Delay after receiving the first SIP 18x response before
declaring the remote end is ringing. If a busy response is
received during this time, the ATA device still considers the
call as failed and keeps on retrying.
The default is 0.5.
Interval between VMWI refresh to the CPE.
The default is 0.5.
Long timeout between entering digits when dialing. The
interdigit timer values are used as defaults when dialing.
The Interdigit_Long_Timer is used after any one digit, if all
valid matching sequences in the dial plan are incomplete
as dialed. Range: 0–64 seconds.
The default is 10.
Short timeout between entering digits when dialing. The
Interdigit_Short_Timer is used after any one digit, if at least
one matching sequence is complete as dialed, but more
dialed digits would match other as yet incomplete
sequences. Range: 0–64 seconds.
The default is 3.
Delay in seconds after caller hangs up when the ATA
device starts removing the tip-and-ring voltage to the
attached equipment of the called party. Range: 0–255
seconds. ATA device has had polarity reversal feature
since release 1.0 which can be applied to both the caller
and the callee end. This feature is generally used for
answer supervision on the caller side to signal to the
attached equipment when the call has been connected
(remote end has answered) or disconnected (remote end
has hung up). This feature should be disabled for the called
party (in other words, by using the same polarity for
connected and idle state) and the CPC feature should be
used instead.
Without CPC enabled, reorder tone will is played after a
configurable delay. If CPC is enabled, dial tone will be
played when tip-to-ring voltage is restored Resolution is 1
second.