AC Good LED
DC Good LED
On
Off
On
On

POST error codes

In the following error codes, X can be any number or letter.
Error Code/Symptom
062 (Three consecutive boot failures using the
default configuration.)
101, 102 (System and processor error)
106 (System and processor error)
111 (Channel check error)
114 (Adapter read-only memory error)
129 (Internal cache error)
151 (Real time clock error)
134
Hardware Maintenance Manual: xSeries 230 Models 6RY, 61Y
Description
Standby mode or dc
problem.
Power is OK.
FRU/Action
1. Run Configuration/Setup
2. Battery
3. System Board
4. Processor
1. System Board
1. System Board
1. Failing ISA Adapter
2. Memory DIMM
3. System Board
1. Failing Adapter
2. Run Diagnostics
1. Processor
2. Optional Processor (if installed)
3. System Board
1. Run Diagnostics
2. Battery
3. System Board
FRU/Action
1. Check system board cable connectors J4
and J15 (system board to power
backplane). Set power-on override switch
(switch 5 of SW1) to On position (see
"System board switches and jumpers" on
page 44). If the DC Good LED comes on,
check the following components:
a. Power Switch Assembly
b. System Board
Note: The power-on override switch
(switch 5 of SW1) is intended for problem
determination purposes only. Use of this
switch will cause POST errors.
2. Remove the adapters and disconnect the
cables and power connectors to all internal
and external devices. Power-on the system.
If the DC Good LED comes on, replace the
adapters and devices one at a time until
you isolate the problem.
3. Power Supply
4. Power Backplane
5. System Board
N/A