Diagnostic Error Codes - IBM xSeries 230 6RY Hardware Maintenance Manual

Table of Contents

Advertisement

Diagnostic Panel LED
PCI B LED on
PCI C LED on
PS1 LED on
PS2 LED on
OVER LED on
SMI LED on
TEMP LED on (Look at test cases.) 1. Ambient temperature must be within normal operating specifications.

Diagnostic error codes

Note: In the following error codes, if XXX is 000, 195, or 197, do not replace a
Error Code/Symptom
001-XXX-000 (Failed core tests)
001-XXX-001 (Failed core tests)
FRU/Action
1. Card in slots 3-5.
2. Remove all PCI adapters from slots 1-5.
3. System Board.
1. Remove all PCI adapters from slots 1-5.
2. System Board.
1. Check the DC Good LED on power supply 1. If off, replace power
supply 1.
2. Power Backplane.
1. Check the DC Good LED on power supply 2. If off, replace power
supply 2.
2. Power Backplane.
1. Install an optional additional power supply, or remove optional devices
from the server.
1. Reboot the system.
See"Features and specifications" on page 3.
2. Ensure fans are operating correctly.
3. Examine System Error Log.
a. System over recommended temperature
1) Information LED Panel
b. DASD over recommended temperature (DASD LED also on)
1) Overheating hard drive
2) DASD Backplane
c. System over recommended temperature for CPU X (where X is CPU 1,
2, 3, or 4) (CPU LED also on)
1) CPU X
2) System Board
4. If the CPU LED on the diagnostics panel is also on, one of the
microprocessors has caused the error.
5. System Board
FRU. The description for these error codes are:
000
The test passed.
195
The Esc key was pressed to abort the test.
197
This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
FRU/Action
1. System Board
1. System Board
129
Symptom-to-FRU index