Error Code/Symptom
2
1302 (I
C cable from system board to power
on and reset switches not found)
2
1303 (I
C cable from system board to power
backplane not found)
2
1304 (I
C cable to diagnostic LED board not
found)
1600 (The Service Processor is not
functioning) Do the following before
replacing a FRU:
1. Ensure that a jumper is not installed on
J51.
2. Remove the ac power to the system, wait
20 seconds; then, re-connect the ac power.
Wait 30 seconds; then, power-on the
system.
1601 (The system is able to communicate to
the Service Processor, but the Service
Processor failed to respond at the start of
POST.) Do the following before replacing a
FRU:
1. Remove the ac power to the system, wait
20 seconds; then, re-connect the ac power.
Wait 30 seconds; then, power-on the
system.
2. Flash update the Service Processor.
1762 (Fixed Disk Configuration error)
178X (Fixed Disk error)
1800 (No more hardware interrupt available
for PCI adapter)
FRU/Action
1. Cable
2. Power Switch Assembly
3. System Board
1. Cable
2. Power Backplane
3. System Board
1. Cable
2. Diagnostic LED Board
3. Power Switch Assembly
4. System Board
1. System Board
1. System Board
1. Fixed Disk Cables
2. Run Configuration/Setup 2
3. Fixed Disk Adapter
4. Fixed Disk Drive
5. SCSI Backplane
6. System Board
1. Fixed Disk Cables
2. Run Diagnostics
3. Fixed Disk Adapter
4. Fixed Disk Drive
5. System Board
1. Run Configuration/Setup
2. Failing Adapter
3. System Board