IBM xSeries 230 6RY Hardware Maintenance Manual page 29

Table of Contents

Advertisement

Table 2. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller (continued)
PCNTNW-NW-058 The adapter did not respond to the initialization command.
PCNTNW-NW-066 The cable might be disconnected from the adapter.
PCNTNW-NW-071 The matching virtual adapter could not be found.
PCNTNW-NW-072 A resource tag is unavailable.
PCNTNW-NW-073 Unable to allocate memory
PCNTNW-NW-074 The hardware interrupt cannot be set.
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered with the
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free
PCNTNW-NW-086 The driver parameter block is too small.
PCNTNW-NW-087 The media parameter block is too small.
Explanation: The interrupt request (IRQ) setting might not be valid or the
EEPROM information might be incorrect. Action: Make sure the IRQ settings
are correct in the Configuration/Setup Utility program. for information on
setting the interrupt requests.
Explanation: The cable might be disconnected from the server Ethernet port.
Action: Verify that a cable is connected to the Ethernet port.
Explanation: You tried to load another instance of the driver with a different
I/O address. This new adapter could not be found. Action: Verify that you
installed an IBM Netfinity 10/100 Fault Tolerant Adapter and make sure that
the adapter is seated correctly.
Explanation: The driver tried to allocate some resources that were not
available. Action: Add more memory, or free some memory resources in the
server. Then, restart the server.
Explanation: The driver failed to allocate the memory needed for normal
operation. Action: Add more memory, or free some memory resources in the
server. Then, restart the server.
Explanation: An attempt was made to initialize a given hardware interrupt.
The attempt was not successful. Action: Verify that the Ethernet controller is
enabled. If the Ethernet controller is enabled, go to "Starting the diagnostic
programs" on page 16 to run the diagnostic programs.
If you have an Ethernet adapter installed, make sure that the adapter does not
share an IRQ with any other device.
Link Support Layer (LSL).
Explanation: An error occurred while the driver was trying to register with the
LSL. Action: Check the version of the NetWare or IntraNetWare Operating
System. Make sure that this driver is correct for the version of NetWare or
IntraNetWare that you are using. Restart the server.
Count.
Explanation: The MSMTx Free Count is not initialized correctly. Action:
Restart the server.
Explanation: The driver parameter block is too small. Action: Restart the
server.
Explanation: The driver media parameter block is too small. Action: Restart
the server.
21
Diagnostics