Error Code/Symptom
00180500 (PCI option ROM checksum error)
00180600 (PCI built-in self test failure) PCI to
PCI Bridge error
00180700, 00180800 (General PCI error)
01295085 (ECC checking hardware test error)
01298001 (No update data for processor 1)
01298002 (No update data for processor 2)
01298101 (Bad update data for processor 1)
01298102 (Bad update data for processor 2)
I9990301 (Fixed boot sector error)
I9990305 (Fixed boot sector error, no
operating system installed)
I9990650 (AC power has been restored)
FRU/Action
1. Remove Failing PCI Card
2. System Board
1. Run Configuration/Setup
2. Move the failing adapter to slot 1 or 2
3. Failing Adapter
4. System Board
1. System Board
2. PCI Card
1. System Board
2. Processor
1. Ensure all processors are the same cache size.
2. Processor 1
1. Ensure all processors are the same cache size.
2. Processor 2
1. Ensure all processors are the same cache size.
2. Processor 1
1. Ensure all processors are the same cache size.
2. Processor 2
1. Hard Disk Drive
2. SCSI Backplane
3. Cable
4. System Board
1. Install operating system to hard disk drive.
1. Check cable
2. Check for interruption of power supply
3. Power Cable
139
Symptom-to-FRU index